Bath Fans with Radiation Dampers
Models: See Below
About Ceiling Radiation Dampers
Hourly-rated floor/ceiling membranes are designed to protect a structure from heat and subsequent potential collapse. Vented fans installed in these assemblies penetrate the fire-resistive membrane. To protect the ducted opening against the spread of heat and fire, many local codes require the installation of a ceiling radiation damper. Installed between the housing and grille, the damper employs an insulation blanket that closes off the opening in an emergency by means of a heat-sensitive fusible link. The ceiling dampers below meet UL Standard 555C and are labeled for use in fire-resistive floor/ceiling membranes.
|
|
Ceiling Radiation Damper
- UL tested and labeled (UL Standard 555C) for use in 1, 2, and 3-hour floor-ceiling and roof-ceiling construction
- removable damper assembly and sleeve to allow easy motor replacement
- UL approved insulation blanket constructed of non-asbestos, high-temperature reinforced fiber thermal curtain
- Heat sensitive 165° replaceable fusible link
- .024 galvanized steel frame
|
Fan Housing
- One-piece, heavy gauge (.024) galvanized steel
- larger wiring compartment provides easy access and installation
- mounts directly to joists with mounting tabs
- housing available with 3" metal or plastic duct collar or 4" plastic duct collar
- extended discharge collar with built-in backdraft damper
|
Motor/Grille
- Available in 50 CFM or 70 CFM models
- Plug-in, permanently lubricated motor rated for 120 volts 60 Hz operation
- Removable motor plate with easy slide-in mounting
- attractive curved grille for efficient airflow and contemporary style
- larger grille covers more of rough-in area
- grille mounts directly to damper with torsion springs
- UL listed for use/shower with GFI branch circuit wiring
|
Download literature about this product.
| Model
| Air Delivery
| Bath Size
| Sones
| Amp
|
| 503 |
50 CFM |
45 sq ft |
4.0 |
0.90 |
| 703 |
70 CFM |
65 sq ft |
5.5 |
1.80 |
| |
| CFRD Dimensions |
L |
W |
H |
| Radiation Damper |
8 1/16" |
7 5/8" |
3 3/4" |
| Housing |
8 1/16" |
7 5/8" |
3 3/4" |
| Assembled Damper/Housing |
8 1/16" |
7 5/8" |
7 1/4" |
| Grille |
10 1/4" |
10 1/4" |
5/8" |
|
M Series Fans with Radiation Dampers
Models: See Below
|
|
Ceiling Radiation Damper
- UL tested and labeled (UL Standard 555C) for use in 1, 2, and 3-hour floor-ceiling and roof-ceiling construction
- removable damper assembly and sleeve to allow easy motor replacement
- UL approved insulation blanket constructed of non-asbestos, high-temperature reinforced fiber thermal curtain
- Heat sensitive 165° replaceable fusible link
- .024 galvanized steel frame
|
Fan Housing
- One-piece, heavy gauge (.024) galvanized steel
- larger wiring compartment provides easy access and installation
- mounts directly to joists with mounting tabs
- housing uses 4" plastic duct collar
- extended discharge collar with built-in backdraft damper
|
Motor/Grille
- Available in 50, 70, 90, and 110 CFM models
- Plug-in, permanently lubricated motor rated for 120 volts 60 Hz operation
- Removable motor plate with easy slide-in mounting
- attractive curved grille for efficient airflow and contemporary style
- larger grille covers more of rough-in area
- UL listed for use/shower with GFI branch circuit wiring
|
Download literature about this product.
| Model
| Air Delivery
| Bath Size
| Sones
| Amp
|
| MRD50 |
52 CFM |
60 sq ft |
2.0 |
0.80 |
| MRD70 |
72 CFM |
85 sq ft |
4.5 |
0.88 |
| MRD90 |
90 CFM |
110 sq ft |
3.5 |
0.55 |
| MRD110 |
110 CFM |
135 sq ft |
3.5 |
0.80 |
| |
| MRD Dimensions |
L |
W |
H |
| Radiation Damper |
9 3/8" |
9 1/2" |
3" |
| Housing |
9 1/4" |
9 3/8" |
5 5/8" |
| Assembled Damper/Housing |
9 3/8" |
9 1/2" |
8" |
| Grille |
12" |
12" |
5/8" |
|
|